B7 exits from rooms and or fire compartments 32.
Means of escape from mezzanine floors.
Care must be taken that further staircases do not discharge too closely as they will then risk being regarded as a single means of escape.
Determination about a building extension and addition of a new mezzanine floor ref sb 007 001 012.
It is a requirement for all mezzanine floors to have a means of escape.
Having a clear means of escape from your commercial mezzanine flooring is a legal requirement according to building regulations part b fire safety.
Section 2 provisions of means of escape.
The requirements for the provision of means of escape from mezzanine floors are set out in the building regulations part b2 fire safety.
Without going into detail there are some exceptions in the code that allows for the mezzanine to be larger given certain factors such as the buildings type of construction and whether the building is equipped with an automatic sprinkler system and emergency communication system.
B8 exits from storeys 33.
Do we need to protect the mezzanine floor from fire.
The means of escape from the floor meets the relevant provisions in sections 4 5 and 6 of b1 horizontal escape.
They need to be factored in when designing your floor space.
As long as the mezzanine floor is for storage use and nobody is permanently stationed on it then no fire protection is required.
Consider that any stairs take up space and will need to be easily accessed.
Means of warning and escape the downloads below relate to part b1 of the building regulations.
Mezzanine floor building regulations uk mezzanine floor building regulations mezzanine floor building regulations applicable to the uk are a crucial part of the initial planning stage for any mezzanine floor we take responsibility to ensure that the mezzanine floor project is designed to current mezzanine floor building regulations including quality standards and best practice guidance.
Different shed mezzanine ideas benefits.
B5 general requirements of exit routes 28.
B6 buildings with only one required staircase 31.
However fire protection may be required if the floor exceeds certain sizes or takes up more than a certain percentage of the available building space.
B2 performance requirements for means of escape 23.
The mezzanine floor is not more than 10m in any direction.
The floor is open above and below to the room or space in which it is situated.
The mezzanine floor does not cover more than 50 of the floor area of the space in which it is situated.
B4 assessment of occupant capacity 25.
Escaping a mezzanine floor in the event of a fire is more complex when compared to a normal business floor keeping your composure is key in these particular situations.
This requirement means you will need to include stairs in the design of your mezzanine floor.
505 2 2 means of egress for mezzanines exiting.